SPB Boiler – Rotary Grate
Location: Candelaria Valle – Colombia
Commercial Operation: 2007
Boiler Technical Data:
- Engineering and Technology: HPB Engenharia e Equipamentos Ltda | B&W
- Maximum Steam Flow: 180,000 kg/h
- Steam Operating Pressure: 67 bar
- Final Steam Temperature: 510 °C
- Main Fuel: Sugarcane bagasse
- Auxiliary Fuel: Coal and bagacillo
- Boiler Thermal Efficiency: 88.5% (LHV) for bagasse and 90.3% (LHV) for coal
- Guaranteed Emissions: CO: < 200 mg/Nm³ | Particulate: < 50 mg/Nm³ | NOx: < 300 mg/Nm³